| Model Name | Isuna D5K-TH | Isuna D6K-TH | Isuna D8K-TH | Isuna D10K-TH | Isuna D12K-TH |
| Off-grid Output | |||||
| Rated Output Power | 5kW | 6kW | 8kW | 10kW | 12kW |
| Max.Output Power | 5.5kVA | 6.6kVA | 8.8kVA | 11kVA | 13.2kVA |
| Peak Power &Duration | 20kVA(10s)* | ||||
| Max.Output Current | 8.3A | 10A | 13.3A | 16A | 20A |
| Rated Output Voltage | 3/N/PE,220/380Vac,230/400Vac | ||||
| Switching Time | <10ms | ||||
| GEN Max.Current | 25.8A | 27.3A | 30.3A | 33.3A | 36.4A |
| GEN Voltage Range | 185-276V(P2N) | ||||
| On-grid Parameter | |||||
| Rated Output Power | 5kW | 6kW | 8kW | 10kW | 12kW |
| Max.Output Power | 5.5kVA | 6.6kVA | 8.8kVA | 11kVA | 13.2kVA |
| Max.Output Current | 8.3A | 10A | 13.3A | 16A | 20A |
| Max.Input Power | 17kVA | 18kVA | 20kVA | 22kVA | 24kVA |
| Rated Voltage | 3/N/PE,220/380Vac,230/400Vac | ||||
| Grid Voltage range | 185-276V(P2N) | ||||
| Grid Frequency | 50/60±5Hz | ||||
| PV Input | |||||
| Max.Input Power | 10000Wp | 12000Wp | 16000Wp | 18000Wp | 18000Wp |
| Max.Input Voltage | 1000V | ||||
| Number of MPPT | 3 | ||||
| Max.Input String Per MPPT | 01/1/1 | ||||
| MPPT Voltage Range | 130-960V | ||||
| Starting Voltage | 140V | ||||
| Max.Input Current | 20A/20A/20A | ||||
| Short-Circuit Current | 24A/24A/24A | ||||
| Battery Parameter | |||||
| Battery Type | Lithium-ion/Lead-Acid/Sodium-ion(optional) | ||||
| Number of Battery Input | 2 | ||||
| Battery Voltage Range | 125-800V | ||||
| Battery Charging/Discharging Current | 25A*2 | ||||
| Efficiency | |||||
| Max.Efficiency | 98.20% | ||||
| European Efficiency | 97.70% | ||||
| Max.Battery Charging/Discharging Efficiency | 97.80% | ||||
| General Data | |||||
| Size(W*H*D) | 400mm*575mm*165mm | ||||
| Weight | 26kg | ||||
| Noise | <45dB | ||||
| Operating Temperature | -25℃~+60℃(>45℃ Derating) | ||||
| Operating Altitude | 4000m(>3000m Derating) | ||||
| Cooling Method | Intelligent Air Cooling | ||||
| Ingress Protection Grade | IP65 | ||||
| Topology | Non-isolated | ||||
| Communication Port | LED/WIFI/4G/Bluetooth/RS485 | ||||
| Protection | DC Switch;Reverse Polarity Protection;AC Overvoltage/Overcurrent/Short Circuit Protection; Anti-islanding Protection;Residual Current Monitoring;Insulation Resistance Detection; Surge Protection:DC Type l/AC Type III;AFCI(Optional);PID(Optional) |
||||
| Certification | |||||
| CE-LVD | IEC62109-1&2,IEC62040-1 | ||||
| CE-EMC | EN61000-6-1,EN61000-6-2,EN61000-6-3,EN61000-6-4, EN 61000-4-16,EN 61000-4-18,EN 61000-4-29 |
||||
| Grid | VDE-AR-N 4105,VDE 0126-1-1 EN 50549-1,G98,G100,CEI 0-21,AS/NZS4777.2 NRS 097-2-1 | ||||